,
חייגו אלינו
03-9000900
Careers
About
Contact Us
UPS
Contact us
Contact UPS Department
Articles
UPS Purchasing Tips
UPS Articles
Computer UPS
Modular UPS System
Outdoor UPS
Server rooms UPS
The importance of an uninterrupted system for servers
Modular UPS Matrix Pro
TOPICS
UPS for Server
Industrial UPS
UPS Communication Equipment
For Computers Workstation
Products
AVR Stabilizers
Interactive UPS
Online UPS
UPS Accessories
Exclusive Solutions
Batteries for ups
Interactive Sine
Transfer Switch
UPS Installation Instructions
Electrical Panels
Power Supplies
Led Driver
1W-100W
100W-500W
500W-1000W
DC/DC Inverter
Industrial
DC/DC PCB/ENCAPSULATED
DC / DC Telecom
DC/DC By Demand
DC/DC Rack Mounting
DC / DC LED lighting and signage
DC/DC Accessories
DC/AC Inverter
DC/AC Solar
DC/AC Sine wave
DC/AC Modified sine inverter
DC/AC Accessories
DC/AC Solutions On Demand
AC/DC Power Supply
Chargers
Din Rail
Industrial
PCB / Open Frame
Externl Adaptor
Rack Mount Power Supply
Compact PCI
Medical Power Supply
Customize Power Supply
Telecom Power Supply
LAB Power Supply
Raged Power Supply
AC/DC Accessories
Capacitor Charger
Articles
Articles power supplies
HBU250/HEU250
Choosing the right power supply
IT2800 Graphical Source Measure Unit
Contact us
Contact Power Supply Department
Solar Systems
Contact us
Contact Solar Department
Articles
Smart Network
Articles About Solar
Power Supply System
Solar System SolarEdge
SolarEdge - Solar System
Advanced solutions for energy storage
Solar System
Energy Storage
Solaradge Converters
Off-Grid Solar System
Batteries for solar systems
Solar System Solar-Log
Servers
Contact Us
Contact Servers Department
Articles
Server Room Builder
Building Server Rooms Tips
Planning and Construction
Designing a small/medium server room
Power Distribution Unit (PDU) for server racks
Redundancy and Flexibility Plans
Proper maintenance of power strips in server rooms
Room Server
ATS / STS
KVM Server Rooms
Server Room Racks
PDU - Power Distribution Units
Monitoring Detectors SNMP
Electrical Panels Solutions
UPS Server Rooms and Industrial
Advice Gold Cabinets
Communication
Cloud Solution
Wireless LAN
Communication Switch
Articles
More Articles
WIFI Wireless Solutions
More Articles
Mesh AP Camera
Server Rack Buying Tip
PDU Buying Guide
Communication Rack
ADVICE GOLD Server Rack
Telecom Products
Power Over Ethernet
Communication Switch
Wireless LAN
Broadband Communication
Media Conversion
PDU - Power Distribution Units
Industrial Communication Products
KVM Switches KVM Console Drawers
Lithium Battaries
Contact us
Contact the lithium battery department
Call us - +972-547-995411
Articles
The future of lithium batteries
Instructions for use and safety
Design and manufacture of lithium batteries
Lithium Battaries
Lithium batteries for energy storage
Lithium batteries for a variety of applications
Lithium batteries for trailers
Assembly of lithium batteries on demand
EV Chargers
Contact us
Contact EV Charger Department
Articles
Electric Vehicle Revolution In Israel
Application for monitoring charging systems
Charger from Advice-EV, the right choice
The Advice app for managing charging stations
The evolution of electric vehicles and chargers
Recommended chargers for electric vehicles from Advice-EV
The world of electric vehicles: a green revolution on wheels
Electric Car Home Charger By ADVICE
DC EV CHARGERS
DC EV CHARGERS
AC EV CHARGERS
Home use
Commercial use
Accessories
Download
Communication
Power Supplies
Eltek Power Supply
User Manual
UPS Software
Remote control
Operating instructions for EV chargers
UPS Installation Instructions
User guide for charging application for electric vehicles
Info
Articles
UPS Articles
Power Supplies Articles
Networks Communication Articles
Solar System Articles
Server Room Articles
Intranet Articles
Info Center
About
Careers
Contact Us
Quality & Certifications
Global Distribution
Or - The Center for Professions and Placement
Solar Energy Production Course
Course in Maintenance, Monitoring, and Performance Optimization of Solar Systems
Customer Service
Contact us
Contact Customer Service
Service Request
Check Warranty Status
Activate Warranty
Refund request form
Check Service Status
Opening a service request for systems 4KVA and above / Service agreement
Shopping Cart
Your cart is currently empty.
Continue Shopping
Home
Fiber Optic Switches
GS-5220-16S8CR
GS-5220-16S8CR
Previous Product
|
Next Product
Product Description
L2+ 24-Port 100/1000X SFP + 8-Port Shared TP Managed Switch
Physical Port
24 100/1000Base-X mini-GBIC/SFP slots
8-port 10/100/1000Base-T Gigabit Ethernet RJ-45, shared with Port-1 to Port-8
RJ45 to RS-232 DB9 console interface for basic management and setup
Layer 2 Features
Prevents packet loss with back pressure (half-duplex) and IEEE 802.3x pause frame flow control (full-duplex)
High performance of Store-and-Forward architecture and runt/CRC filtering eliminates erroneous packets to optimize the network bandwidth
Storm Control support
- Broadcast / Unicast / Unknown Unicast
Supports VLAN
- IEEE 802.1Q tagged VLAN
- Up to 255 VLANs groups, out of 4095 VLAN IDs
- Provider Bridging (VLAN Q-in-Q) support (IEEE 802.1ad)
- Private VLAN Edge (PVE)
- Protocol-based VLAN
- MAC-based VLAN
- IP Subnet-based VLAN
- Voice VLAN
Supports Spanning Tree Protocol
- STP, IEEE 802.1D Spanning Tree Protocol
- RSTP, IEEE 802.1w Rapid Spanning Tree Protocol
- MSTP, IEEE 802.1s Multiple Spanning Tree Protocol, spanning tree by VLAN
- BPDU Guard
Supports Link Aggregation
- 802.3ad Link Aggregation Control Protocol (LACP)
- Cisco ether-channel (Static Trunk)
- Maximum 12 trunk groups, up to 8 ports per trunk group
- Up to 16Gbps bandwidth (full duplex mode)
Provides Port Mirror (many-to-1)
Port Mirroring to monitor the incoming or outgoing traffic on a particular port
Loop protection to avoid broadcast loops
Layer 3 IP Routing Features
Supports maximum 128 static routes and route summarization
Quality of Service
Ingress Shaper and Egress Rate Limit per port bandwidth control
8 priority queues on all switch ports
Traffic classification
- IEEE 802.1p CoS
- TOS / DSCP / IP Precedence of IPv4/IPv6 packets
- IP TCP/UDP port number
- Typical network application
Strict priority and Weighted Round Robin (WRR) CoS policies
Traffic-policing policies on the switch port
DSCP remarking
Multicast
Supports IGMP Snooping v1, v2 and v3
Supports MLD Snooping v1 and v2
Querier mode support
IGMP Snooping port filtering
MLD Snooping port filtering
MVR (Multicast VLAN Registration)
Security
IEEE 802.1X Authentication with Guest VLAN
Built-in RADIUS client to cooperate with the RADIUS servers
RADIUS / TACACS+ users access authentication
IP-based Access Control List (ACL)
MAC-based Access Control List (ACL)
Source MAC / IP address binding
DHCP Snooping to filter distrusted DHCP messages
Dynamic ARP Inspection discards ARP packets with invalid MAC address to IP address binding
IP Source Guard prevents IP spoofing attacks
IP address access management to prevent unauthorized intruder
Management
Switch Management Interfaces
- Console / Telnet Command Line Interface
- Web switch management
- SNMP v1, v2c, and v3 switch management
- SSH / SSL secure access
Four RMON groups (history, statistics, alarms and events)
IPv6 Address / NTP management
Built-in Trivial File Transfer Protocol (TFTP) client
BOOTP and DHCP for IP address assignment
Firmware upload / download via HTTP / TFTP
DHCP Relay and Option 82
User Privilege levels control
NTP (Network Time Protocol)
Link Layer Discovery Protocol (LLDP)
SFP-DDM (Digital Diagnostic Monitor)
Cable Diagnostic technology provides the mechanism to detect and report potential cabling issues for TP ports
ICMPv6 / ICMPv4 Remote Ping
Reset button for system reboot or reset to factory default
SMTP / Syslog / SNMP Trap remote alarm
System Log
PLANET Smart Discovery Utility for deploy management
Redundant Power System (GS-5220-16S8CR)
Redundant 100~240V AC / 36-60V DC dual power
Active-active redundant power failure protection
Backup of catastrophic power failure on one supply
Fault tolerance and resilience
Specification
Specification GS-5220-16S8CR EN