{"id":2098422448177,"title":"STS\/ATS - תלת פאזי","handle":"sts-ats-three-phase","description":"\u003cdiv style=\"direction: rtl; text-align: left;\"\u003e\u003cstrong\u003e3 Phase in 3 Phase out \/ 50Amp to 400Amp\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"direction: rtl; text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli style=\"direction: ltr;\"\u003eCompact size\u003c\/li\u003e\n\u003cli style=\"direction: ltr;\"\u003eIncreased power quality\u003c\/li\u003e\n\u003cli style=\"direction: ltr;\"\u003eEasy monitoring all parameters on LCD display\u003c\/li\u003e\n\u003cli style=\"direction: ltr;\"\u003eFast microcontroller (32 mips(\u003c\/li\u003e\n\u003cli style=\"direction: ltr;\"\u003ePower blackout protection\u003c\/li\u003e\n\u003cli style=\"direction: ltr;\"\u003eAutomatic static switching\u003c\/li\u003e\n\u003cli style=\"direction: ltr;\"\u003eRemote monitoring of input power sources\u003c\/li\u003e\n\u003cli style=\"direction: ltr;\"\u003eEasy static and mechanical transfer between separate input sources\u003c\/li\u003e\n\u003cli style=\"direction: ltr;\"\u003eRemote management of power events\u003c\/li\u003e\n\u003cli style=\"direction: ltr;\"\u003ePower event logging\u003c\/li\u003e\n\u003cli style=\"direction: ltr;\"\u003eAdvanced RS232 communication features\u003c\/li\u003e\n\u003cli style=\"direction: ltr;\"\u003eDRY contact alarm interface\u003c\/li\u003e\n\u003cli style=\"direction: ltr;\"\u003ePassword protected login system from remote site (timed Access(\u003c\/li\u003e\n\u003cli style=\"direction: ltr;\"\u003e2 redundant power supplies for electronic boards (hot swappable(\u003c\/li\u003e\n\u003cli style=\"direction: ltr;\"\u003eEasy front access to all components inside of the STS\u003c\/li\u003e\n\u003cli style=\"direction: ltr;\"\u003eSecond protection cover on live circuits which prevents electrical shock\u003c\/li\u003e\n\u003cli style=\"direction: ltr;\"\u003eInput sources protected by fuses\u003c\/li\u003e\n\u003cli style=\"direction: ltr;\"\u003e3 positioned Maintenance bypass switch which prevents cross currents between input sources\u003c\/li\u003e\n\u003cli style=\"direction: ltr;\"\u003eUser adjustable parameters by entering a password\u003c\/li\u003e\n\u003cli style=\"direction: ltr;\"\u003eBuilt in real time clock\u003c\/li\u003e\n\u003cli style=\"direction: ltr;\"\u003eAlarm history (with their date and time(\u003c\/li\u003e\n\u003cli style=\"direction: ltr;\"\u003eAutomatic transfer test from a remote site or using front panel\u003c\/li\u003e\n\u003cli style=\"direction: ltr;\"\u003eFront panel Lamp test\u003c\/li\u003e\n\u003cli style=\"direction: ltr;\"\u003eExternal emergency shutdown (EPO) input\u003c\/li\u003e\n\u003cli style=\"direction: ltr;\"\u003eHot plug construction during maintenance bypass\u003c\/li\u003e\n\u003cli style=\"direction: ltr;\"\u003eHigh current output tolerant up to 1000%\u003c\/li\u003e\n\u003cli style=\"direction: ltr;\"\u003eTemperature sensor inside the Cabinet\u003c\/li\u003e\n\u003cli style=\"direction: ltr;\"\u003eFast voltage black-out circuit\u003c\/li\u003e\n\u003cli style=\"direction: ltr;\"\u003eInput phase balance and phase sequence fault detect circuit\u003c\/li\u003e\n\u003cli style=\"direction: ltr;\"\u003eAdjustable Input source frequency lower\/upper limits\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"direction: rtl; text-align: left;\"\u003e \u003c\/p\u003e\n\u003cp style=\"direction: rtl; text-align: left;\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"direction: rtl; text-align: left;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0036\/9413\/3297\/files\/specification_three_phase-sts_ats_NEW_EN.pdf?5639\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003cstrong\u003eSpecification STS\/ATS EN\u003c\/strong\u003e\u003c\/span\u003e\u003c\/a\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0036\/9413\/3297\/files\/specification_three_phase-sts_ats_NEW_EN.pdf?5639\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e\u003cspan\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0036\/9413\/3297\/files\/pdf.image_480x480.jpg?v=1575538069\" alt=\"\"\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e","published_at":"2019-07-29T06:37:03-04:00","created_at":"2019-07-29T06:39:04-04:00","vendor":"ADVICE.CO.IL","type":"","tags":["UPS"],"price":0,"price_min":0,"price_max":0,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":16014567014449,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"STS\/ATS - תלת פאזי","public_title":null,"options":["Default Title"],"price":0,"weight":0,"compare_at_price":null,"inventory_management":"shopify","barcode":""}],"images":["\/\/cdn.shopify.com\/s\/files\/1\/0036\/9413\/3297\/products\/stsats_main_500_1.png?v=1577890400"],"featured_image":"\/\/cdn.shopify.com\/s\/files\/1\/0036\/9413\/3297\/products\/stsats_main_500_1.png?v=1577890400","options":["Title"],"media":[{"alt":"STS\/ATS - תלת פאזי - ADVICE.CO.IL","id":2392545394737,"position":1,"preview_image":{"aspect_ratio":1.0,"height":500,"width":500,"src":"https:\/\/cdn.shopify.com\/s\/files\/1\/0036\/9413\/3297\/products\/stsats_main_500_1.png?v=1569517379"},"aspect_ratio":1.0,"height":500,"media_type":"image","src":"https:\/\/cdn.shopify.com\/s\/files\/1\/0036\/9413\/3297\/products\/stsats_main_500_1.png?v=1569517379","width":500}],"content":"\u003cdiv style=\"direction: rtl; text-align: left;\"\u003e\u003cstrong\u003e3 Phase in 3 Phase out \/ 50Amp to 400Amp\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"direction: rtl; text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cul style=\"text-align: left;\"\u003e\n\u003cli style=\"direction: ltr;\"\u003eCompact size\u003c\/li\u003e\n\u003cli style=\"direction: ltr;\"\u003eIncreased power quality\u003c\/li\u003e\n\u003cli style=\"direction: ltr;\"\u003eEasy monitoring all parameters on LCD display\u003c\/li\u003e\n\u003cli style=\"direction: ltr;\"\u003eFast microcontroller (32 mips(\u003c\/li\u003e\n\u003cli style=\"direction: ltr;\"\u003ePower blackout protection\u003c\/li\u003e\n\u003cli style=\"direction: ltr;\"\u003eAutomatic static switching\u003c\/li\u003e\n\u003cli style=\"direction: ltr;\"\u003eRemote monitoring of input power sources\u003c\/li\u003e\n\u003cli style=\"direction: ltr;\"\u003eEasy static and mechanical transfer between separate input sources\u003c\/li\u003e\n\u003cli style=\"direction: ltr;\"\u003eRemote management of power events\u003c\/li\u003e\n\u003cli style=\"direction: ltr;\"\u003ePower event logging\u003c\/li\u003e\n\u003cli style=\"direction: ltr;\"\u003eAdvanced RS232 communication features\u003c\/li\u003e\n\u003cli style=\"direction: ltr;\"\u003eDRY contact alarm interface\u003c\/li\u003e\n\u003cli style=\"direction: ltr;\"\u003ePassword protected login system from remote site (timed Access(\u003c\/li\u003e\n\u003cli style=\"direction: ltr;\"\u003e2 redundant power supplies for electronic boards (hot swappable(\u003c\/li\u003e\n\u003cli style=\"direction: ltr;\"\u003eEasy front access to all components inside of the STS\u003c\/li\u003e\n\u003cli style=\"direction: ltr;\"\u003eSecond protection cover on live circuits which prevents electrical shock\u003c\/li\u003e\n\u003cli style=\"direction: ltr;\"\u003eInput sources protected by fuses\u003c\/li\u003e\n\u003cli style=\"direction: ltr;\"\u003e3 positioned Maintenance bypass switch which prevents cross currents between input sources\u003c\/li\u003e\n\u003cli style=\"direction: ltr;\"\u003eUser adjustable parameters by entering a password\u003c\/li\u003e\n\u003cli style=\"direction: ltr;\"\u003eBuilt in real time clock\u003c\/li\u003e\n\u003cli style=\"direction: ltr;\"\u003eAlarm history (with their date and time(\u003c\/li\u003e\n\u003cli style=\"direction: ltr;\"\u003eAutomatic transfer test from a remote site or using front panel\u003c\/li\u003e\n\u003cli style=\"direction: ltr;\"\u003eFront panel Lamp test\u003c\/li\u003e\n\u003cli style=\"direction: ltr;\"\u003eExternal emergency shutdown (EPO) input\u003c\/li\u003e\n\u003cli style=\"direction: ltr;\"\u003eHot plug construction during maintenance bypass\u003c\/li\u003e\n\u003cli style=\"direction: ltr;\"\u003eHigh current output tolerant up to 1000%\u003c\/li\u003e\n\u003cli style=\"direction: ltr;\"\u003eTemperature sensor inside the Cabinet\u003c\/li\u003e\n\u003cli style=\"direction: ltr;\"\u003eFast voltage black-out circuit\u003c\/li\u003e\n\u003cli style=\"direction: ltr;\"\u003eInput phase balance and phase sequence fault detect circuit\u003c\/li\u003e\n\u003cli style=\"direction: ltr;\"\u003eAdjustable Input source frequency lower\/upper limits\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"direction: rtl; text-align: left;\"\u003e \u003c\/p\u003e\n\u003cp style=\"direction: rtl; text-align: left;\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"direction: rtl; text-align: left;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0036\/9413\/3297\/files\/specification_three_phase-sts_ats_NEW_EN.pdf?5639\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003cstrong\u003eSpecification STS\/ATS EN\u003c\/strong\u003e\u003c\/span\u003e\u003c\/a\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0036\/9413\/3297\/files\/specification_three_phase-sts_ats_NEW_EN.pdf?5639\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e\u003cspan\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0036\/9413\/3297\/files\/pdf.image_480x480.jpg?v=1575538069\" alt=\"\"\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e"}

STS/ATS - תלת פאזי

תיאור מוצר
הכמות המרבית הזמינה הושגה
3 Phase in 3 Phase out / 50Amp to 400Amp

  • Compact size
  • Increased power quality
  • Easy monitoring all parameters on LCD display
  • Fast microcontroller (32 mips(
  • Power blackout protection
  • Automatic static switching
  • Remote monitoring of input power sources
  • Easy static and mechanical transfer between separate input sources
  • Remote management of power events
  • Power event logging
  • Advanced RS232 communication features
  • DRY contact alarm interface
  • Password protected login system from remote site (timed Access(
  • 2 redundant power supplies for electronic boards (hot swappable(
  • Easy front access to all components inside of the STS
  • Second protection cover on live circuits which prevents electrical shock
  • Input sources protected by fuses
  • 3 positioned Maintenance bypass switch which prevents cross currents between input sources
  • User adjustable parameters by entering a password
  • Built in real time clock
  • Alarm history (with their date and time(
  • Automatic transfer test from a remote site or using front panel
  • Front panel Lamp test
  • External emergency shutdown (EPO) input
  • Hot plug construction during maintenance bypass
  • High current output tolerant up to 1000%
  • Temperature sensor inside the Cabinet
  • Fast voltage black-out circuit
  • Input phase balance and phase sequence fault detect circuit
  • Adjustable Input source frequency lower/upper limits

 

Specification

Specification STS/ATS EN